Monitor forty, 41, 441, 2400- Recommended to exist done one time every three years:

Inspecting your organisation, Full Monitor Cleaning. Unit to be set to manufactory specs.
Check bearings, Make clean all fans, Clean pwb board/bank check
wire connections, Clean cabinet, Make clean grill, Make clean drip pan, Make clean strainer,
Bank check for debris, Check flame detective plug, Air flow bank check with special
Manometer guages, Set up air to fuel ratio, Necessary tools, material and labor to
perform described job. All taxes included.

Replacement of all itemized parts listed beneath:

New Combustion Burner Band
New Front Bedchamber gasket
New filter cartridge at tank Flame detective plug packing Damper o-ring Labor/Service

*Combustion Blower motor bearing replacement, add $125.00 per heater. Reg. accuse is $225.00 *More than than One? Deduct $10.00 per heater at same location.

*Pressure testing for fumes, add together $35.00

*High Temperature Exhaust O-rings, add together $seven.00 each for extension kits. *Whatever unforeseen items, potential issues or recommendations will be addressed and discussed with an
estimate of boosted price.

*Exterior tank? Add together K-1 PLUS for $xvi.00 per 250 gallons for moisture/water dispersment.

*Heaters with no history of maintainance must have damper o-ring changed. An addtional $15.00 will be added.

$649.00

Monitor 40, 41, 441, 2400 - Recommended to be done once every six years:

Inspecting your system, Full Monitor Cleaning. Unit to exist set to factory specs.
Bank check bearings, Clean all fans, Clean pwb board/check
wire connections, Clean cabinet, Clean grill, Clean drip pan, Clean strainer,
Check for debris, Cheque flame detective plug, Air menstruum bank check with special
Manometer guages, Set air to fuel ratio, Necessary tools, material and labor to
perform described job. All taxes included.

Replacement of all itemized parts listed below:

New Combustion Burner Pot Associates
New Combustion Burner Ring
New Front Bedchamber gasket
New filter cartridge at tank
Flame detective plug packing
Damper o-band
Small-scale and Big O-band at exhaust flue
O-gasket for ignitor
Combustion chamber gasket at Base of operations
Heater Cover packing
Truck Supplies
Labor/Service

$899.00

(NOTE: THIS LEVEL OF SERVICE IS NO LONGER Bachelor HERE AT PERFECT PLUMBING AND HEATING, INC.   HITACHI SUSPENDED PRODUCTION OF HEATERS AND PARTS IN 2007.  THERE ARE NO ORIGINAL HITACHI BURNER POT ASSEMBLY'S Available!   Besides, THERE ARE NO ORIGINAL HITACHI HEAT EXCHANGERS Bachelor!  - IF THESE PARTS ARE NEEDED - A NEW TOYOSTOVE LASER 731 OR 732 IS RECOMMENDED!!

WE HAVE NEW TOYOSTOVE UNITS IN STOCK! - Please CALL FOR AVAILABILITY AND PRICING.)

Greetings,

At present that warmer weather is finally here, many of yous have stopped using your heaters for the summer months and now would be an first-class fourth dimension to have the routine tri-annual maintenance performed.

Monitor Heaters do require periodic maintenance at well-nigh three years of service. Occasionally, there are problems that arise after 3 years.

We will thoroughly clean your heater or hot h2o heater and inspect/check for any potential problems such as water in your outside tank, noisy motors, oil lines, installation, etc. As well if applicable, we will advise you of any new state code updates. Some of which, have been recently made into issue and inform you of what any additional costs could be to repair or update a condition.

Nosotros encourage you if you have any intentions of having your unit serviced this spring/summer to deed soon!

Please call today for more than information and consider the benefits while assuasive us to serve you more efficiently during our off peak season instead of waiting for the fall rush. Complete Financing is available through MasterCard, Visa, and Find or with one of our Domicile Source Plans.

From plumbing, heating and oil services, we wait forward to bringing new ideas, innovations and new technology to assistance save y'all money.

Richard E. Burke, Jr.
Perfect Plumbing and Heating, Inc.
Maximum Energy

>Get maximum efficiency and economy from your Monitor Heating System>

Monitor 21, 22, 422, 2200 - Recommended to exist done once every iii years:

Inspecting your arrangement, Full Monitor Cleaning. Unit to be set to manufactory specs.
Check bearings, Make clean all fans, Make clean pwb board/bank check
wire connections, Clean cabinet, Clean grill, Clean drip pan, Clean strainer,
Bank check for debris, Check flame detective plug, Air menstruation check with special
Manometer guages, Set air to fuel ratio, Necessary tools, material and labor to
perform described job. All taxes included.

Replacement of all itemized parts listed below:

New Combustion Burner Pot Associates
New Combustion Burner Ring
New Front Chamber gasket
New filter cartridge at tank
Flame detective plug packing
Damper o-ring
Small and Large O-ring at exhaust flue
O-gasket for ignitor
Combustion chamber gasket at Base
Heater Cover packing
Truck Supplies
Labor/Service

$699.00

$799.00 for 2200 Model Only!

*Option up and drop off fee, add together $200.00 for one heater.  $150 each for two.  $100 each for three.

*Combustion Blower motor replacement, add $225.00 per heater. Reg. charge is $325.00

*More than One? Deduct $10.00 per heater at same location.

*Pressure testing for fumes, add together $35.00

*High Temperature Exhaust O-rings, add $5.00 each for extension kits.

*Any unforeseen items, potential bug or recommendations will be addressed and discussed with an
gauge of boosted price.

*Outside tank? Add Yard-one PLUS for $16.00 per 250 gallons for moisture/water dispersment.

*Suction case comprehend, add $85.00

Note: No heat ten changers for 21, 22, 422, 2200 are available.